MIHA Copper Check Valve φ60

MIHA Copper Check Valve φ60

The φ60 copper check valve is commonly used in water supply systems, fire protection (PCCC), compressed air, and light oil applications. With a size of φ60 (equivalent to DN50 – 2 inches), the valve is made of high-quality brass, ensuring durability, corrosion resistance, and safety for potable water.

In Vietnam, Minh Hòa (MIHA) is a leading reputable brand in brass valve manufacturing, meeting international standards and chosen by many residential and industrial projects.

Outstanding Features of the φ60 Copper Check Valve

The MIHA DN50 brass check valve is always a top choice for residential and industrial applications due to its superior advantages:

  • High-quality brass material: Offers excellent oxidation and corrosion resistance, ensuring long service life and hygiene for the water supply.
  • Compact design: Easy to install even in tight spaces, with simplified maintenance and replacement.
  • Quiet and tight operation: Prevents backflow effectively without creating annoying noise, protecting pumps and other equipment.
  • Variety of designs: Available as swing check valves and spring check valves, allowing easy selection based on specific needs.
  • High pressure and temperature resistance: Operates stably under high pressure (up to 20 Bar) and temperatures up to 120°C, depending on the model.

Các loại van 1 chiều đồng MIHA DN50

Types of MIHA DN50 Copper Check Valves

Model Valve Type Size Pressure (Bar) Max Temperature (°C) Length (mm) Diameter D (mm) Material
MIHA – Spring Spring Check DN50 (φ60) 16 90 98 77 Brass
MIHA – Swing Swing Check DN50 (φ60) 20 120 82 80 Brass
MIHA – Swing (Brass Seat) Swing Check DN50 (φ60) 16 120 90 95 Brass

Connection: Threaded BS 21 / ISO 228-1:2000

Practical Applications of the φ60 Copper Check Valve

Thanks to its excellent features, the MIHA φ60 copper check valve is widely applied and highly effective in many fields:

  • Residential water supply systems: Installed immediately after the pump to prevent backflow, keeping the system stable.
  • Fire protection systems (PCCC): Protect fire pumps from reverse pressure, ensuring absolute safety during emergencies.
  • Compressed air and light oil pipelines: Prevent leakage and protect other system equipment.
  • Industrial and residential projects: From factories and production workshops to residential complexes.

Economic Benefits of Using φ60 Copper Check Valve

Using MIHA brass valves not only ensures smooth system operation but also brings clear economic benefits:

  • Reduced maintenance costs: Durable material minimises repair and replacement expenses.
  • Optimised performance: Ensures smooth and stable system operation, avoiding energy waste.
  • Reasonable price: Competitively priced compared to stainless steel or cast iron valves, making MIHA brass valves a smart and cost-effective investment.
  • Extended pump lifespan: Protects pumps from damage caused by backflow, prolonging equipment life.

Van một chiều đồng phi 60Copper Check Valve φ60

Installation & Maintenance Instructions

Proper installation and periodic maintenance are crucial for the stable operation, long lifespan, and safety of the MIHA φ60 check valve.

Installation Instructions for DN50 Swing and Spring Brass Check Valves

Step 1: Pre-installation Check

  • Ensure valve size and thread standard (BS 21 / ISO 228-1:2000) match the pipeline.
  • Check that threaded surfaces are clean and free of debris or burrs.

Step 2: Determine Flow Direction

  • Observe the arrow cast on the valve body to ensure correct flow direction for effective operation.

Step 3: Installation

  • Threaded connection: Use PTFE tape or thread sealant, install the valve in position, and tighten moderately to avoid cracking the valve body.
  • Recommended installation position: After the pump or before devices needing protection, either vertically or horizontally, depending on system design.

Step 4: Post-installation Check

  • Test the system, observe the valve’s opening/closing, and check for leaks at connections.

Maintenance Instructions

Maintenance cycle:

  • Inspect and clean the valve every 3–6 months, depending on operating conditions (clean water, hard water, or with impurities).

Maintenance steps:

  1. Release pressure and drain the fluid from the pipeline before removing the valve.

  2. Remove the valve, clean the disc, seal, and body using clean water or a mild cleaning solution.

  3. Check the seal and spring (for spring valves), and replace if worn, torn, or lost elasticity.

Safety precautions:

  • Avoid using strong corrosive chemicals or metal brushes to prevent damage to brass surfaces and seals.
  • Ensure connections are tightened properly during reinstallation.

The MIHA φ60 copper check valve is a reliable solution to improve system efficiency and protection. For convenient maintenance without affecting the entire system, it is recommended to install isolation valves before and after the check valve.

For the latest price or detailed consultation, contact Bao Tin Steel – official MIHA distributor: