ShinYi H100 Float Control Valve

Are you seeking an effective solution to regulate the water level in tanks or reservoirs? The ShinYi H100 Float Control Valve (Remote Float Control Valve) is a reliable choice for your water supply system.

With its modern design and fully hydraulic operation that requires no electricity, the valve automatically regulates water levels safely, efficiently, and cost-effectively. In particular, the product is manufactured according to international standards and is highly durable in various working environments, from residential to industrial applications.

Van phao Shin Yi H100
ShinYi H100 Float Control Valve

Outstanding Features of the ShinYi H100 Float Control Valve

Not only known as an intelligent solution for water level control, but the ShinYi H100 float valve also offers numerous superior advantages, making it a trusted choice among engineers in both residential and industrial systems.

  • Hydraulic operation, no electricity required: Ensures safety while saving energy.
  • Accurate water level control: The float rises and falls in response to the water level in the tank, allowing the valve to open and close smoothly and maintain a stable water level, preventing overflow or depletion.
  • High durability with high-quality materials: The valve body is made of ductile iron, while key components, including the stem, disc, and spring, are made of stainless steel 304. The diaphragm is constructed from EPDM rubber reinforced with nylon fabric, offering excellent corrosion resistance and long service life.
  • Durable epoxy coating: The epoxy resin coating, 250–300µm thick in blue or red, protects the valve from environmental impacts and extends its lifespan.
  • Stable operation: The optimised design minimizes the intrusion of debris in the water source, reduces clogging, and ensures smooth, uninterrupted flow.
  • Complies with multiple international standards: Manufactured according to BS, DIN, JIS, ANSI… standards to meet strict requirements for water supply system installation and operation.

Technical Specifications of the ShinYi H100 Float Control Valve

To give you a clearer overview, below is the detailed technical specification table of the ShinYi H100 float control valve, referenced from the manufacturer’s catalogue. It includes size, design standards, and operating parameters:

Attribute Specification
Model H100 – Remote Float Control Valve
Size DN50 – DN600
Design Standards BS EN 1074-5, BS 5163-2
Flange Face-to-Face Standards BS EN 558-1, ISO 5752 Table 1 Series 1
Connection Type Flanged
Working Pressure PN10, PN16, PN25 / JIS 10K, 16K, 20K / ANSI 150LB
Coating Epoxy Resin Powder, 250–300µm thick, Blue/Red
Coating Standard JIS K 5551:2002 (TCVN 9014:2011)
Operating Temperature -10°C ~ 80°C
Application Water Systems
Main Materials Valve Body: Ductile Iron (ASTM A536 / EN GJS 500-7) Disc, Stem, Spring: Stainless Steel 304 Diaphragm: EPDM Rubber + Nylon Fabric

 

Cấu tạo chi tiết van phao Shinyi
Detailed structure of the Shinyi float valve

Detailed Dimension Table

DN (mm) Model/No. L (mm) D (mm) K (mm) H (mm) No. of Bolts – Ød (mm) Weight (kg)
50 H100-0050 230 165 125 269 4 – Ø19 19
65 H100-0065 290 185 145 299 4 – Ø19 19
80 H100-0080 310 200 160 326 8 – Ø19 19
100 H100-0100 350 220 180 371 8 – Ø19 19
125 H100-0125 350 250 210 371 8 – Ø19 19
150 H100-0150 480 285 240 478 8 – Ø23 19
200 H100-0200 600 340 295 579 8 – Ø23 / 12 – Ø23 20
250 H100-0250 730 405 350 / 355 681 12 – Ø23 / 12 – Ø28 22
300 H100-0300 850 445 / 460 400 / 410 758 12 – Ø23 / 12 – Ø28 24.5
350 H100-0350 980 505 / 520 460 / 470 849 16 – Ø23 / 16 – Ø28 24.5
400 H100-0400 1,100 565 / 580 515 / 525 916 16 – Ø26 / 16 – Ø31 24.5
500 H100-0500 1,250 670 / 715 620 / 650 1,080 20 – Ø26 / 20 – Ø34 26.5
600 H100-0600 1,450 780 / 840 725 / 770 1,260 20 – Ø30 / 20 – Ø37 30

Practical Applications of the ShinYi H100 Float Control Valve

With its specialized design and high durability, the ShinYi H100 float control valve is widely used in various water supply systems and infrastructure projects. The product is not only suitable for residential-scale applications but is also trusted in large industrial systems:

  • Domestic water storage tanks are used in apartment buildings, residential areas, and households.
  • Urban water supply systems: Used in pumping stations and intermediate reservoirs to ensure a continuous and safe water supply.
  • Clean water treatment plants: Controls water levels in settling tanks and filtration tanks, preventing overflow or depletion.
  • Agricultural irrigation systems: Help maintain stable water levels in ponds, reservoirs, or storage tanks used for irrigation.
  • Industrial zones and manufacturing plants: Applied in technical storage tanks to ensure stable operation processes and reduce the need for manual supervision.

Economic Benefits of Using the ShinYi H100 Float Control Valve

Beyond operational stability, the ShinYi H100 float control valve helps both businesses and end users optimise various costs throughout its lifecycle:

  • Energy savings: The valve operates entirely by hydraulics without requiring electricity, reducing long-term energy expenses.
  • Lower maintenance costs: Its design minimizes debris intrusion, reduces damage, and extends equipment lifespan, thereby decreasing repair frequency.
  • Improved operational efficiency: Automatic water level control reduces the need for manual supervision and streamlines workflow processes.
  • Reduced risk of damage: Prevents tank overflow or depletion, minimizing water loss and potential property damage.
  • Long-term investment: With premium materials such as ductile iron, stainless steel 304, and EPDM diaphragms, the product maintains excellent durability for many years, delivering sustainable economic value.

Installation & Maintenance Guide for the ShinYi H100 Float Control Valve

To ensure the ShinYi H100 float control valve operates efficiently and remains durable, it is essential to follow the installation and maintenance procedures recommended by the manufacturer:

Hướng dẫn lắp đặt van phao Shin Yi

Shin Yi float valve installation instructions

Installation Instructions

  • Prepare clean piping: Before installation, flush out any debris or impurities in the pipeline to prevent interference with valve operation.
  • Install according to flow direction: The float valve must be installed following the arrow marked on the valve body to ensure proper operation.
  • Connect to the control float: Attach the float at the appropriate position in the tank/reservoir so the valve can open and close accurately according to the water level.
  • Use proper sealing gaskets: When installing with flanges, use standard rubber gaskets to prevent leakage.
  • Integrate auxiliary devices: It is recommended to install a shut-off valve, strainer, and pressure gauge upstream of the float valve for easier monitoring and maintenance.

Maintenance Instructions

  • Periodic inspection: The valve should be checked every 3–6 months to detect early signs of wear, leakage, or float sticking.
  • Clean the float and strainer: Ensure the float and all openings remain clean to prevent debris from obstructing operation.
  • Replace gaskets or diaphragms when necessary: If the valve’s opening/closing response becomes sluggish, replace the gasket or diaphragm to maintain performance.
  • Store in a dry environment when not in use: If the valve is not installed immediately, keep it in a dry, ventilated warehouse to prevent rust.

The above provides an overview of the ShinYi float valve and its operating guidelines. If you are looking for a reliable supplier of genuine ShinYi H100 float valves at competitive prices, contact Bao Tin Steel, a trusted distributor of steel pipes, industrial valves, and fire-fighting equipment.