Are you seeking an effective solution to regulate the water level in tanks or reservoirs? The ShinYi H100 Float Control Valve (Remote Float Control Valve) is a reliable choice for your water supply system.
With its modern design and fully hydraulic operation that requires no electricity, the valve automatically regulates water levels safely, efficiently, and cost-effectively. In particular, the product is manufactured according to international standards and is highly durable in various working environments, from residential to industrial applications.

Outstanding Features of the ShinYi H100 Float Control Valve
Not only known as an intelligent solution for water level control, but the ShinYi H100 float valve also offers numerous superior advantages, making it a trusted choice among engineers in both residential and industrial systems.
- Hydraulic operation, no electricity required: Ensures safety while saving energy.
- Accurate water level control: The float rises and falls in response to the water level in the tank, allowing the valve to open and close smoothly and maintain a stable water level, preventing overflow or depletion.
- High durability with high-quality materials: The valve body is made of ductile iron, while key components, including the stem, disc, and spring, are made of stainless steel 304. The diaphragm is constructed from EPDM rubber reinforced with nylon fabric, offering excellent corrosion resistance and long service life.
- Durable epoxy coating: The epoxy resin coating, 250–300µm thick in blue or red, protects the valve from environmental impacts and extends its lifespan.
- Stable operation: The optimised design minimizes the intrusion of debris in the water source, reduces clogging, and ensures smooth, uninterrupted flow.
- Complies with multiple international standards: Manufactured according to BS, DIN, JIS, ANSI… standards to meet strict requirements for water supply system installation and operation.
Technical Specifications of the ShinYi H100 Float Control Valve
To give you a clearer overview, below is the detailed technical specification table of the ShinYi H100 float control valve, referenced from the manufacturer’s catalogue. It includes size, design standards, and operating parameters:
| Attribute | Specification |
|---|---|
| Model | H100 – Remote Float Control Valve |
| Size | DN50 – DN600 |
| Design Standards | BS EN 1074-5, BS 5163-2 |
| Flange Face-to-Face Standards | BS EN 558-1, ISO 5752 Table 1 Series 1 |
| Connection Type | Flanged |
| Working Pressure | PN10, PN16, PN25 / JIS 10K, 16K, 20K / ANSI 150LB |
| Coating | Epoxy Resin Powder, 250–300µm thick, Blue/Red |
| Coating Standard | JIS K 5551:2002 (TCVN 9014:2011) |
| Operating Temperature | -10°C ~ 80°C |
| Application | Water Systems |
| Main Materials | Valve Body: Ductile Iron (ASTM A536 / EN GJS 500-7) Disc, Stem, Spring: Stainless Steel 304 Diaphragm: EPDM Rubber + Nylon Fabric |

Detailed Dimension Table
| DN (mm) | Model/No. | L (mm) | D (mm) | K (mm) | H (mm) | No. of Bolts – Ød (mm) | Weight (kg) |
|---|---|---|---|---|---|---|---|
| 50 | H100-0050 | 230 | 165 | 125 | 269 | 4 – Ø19 | 19 |
| 65 | H100-0065 | 290 | 185 | 145 | 299 | 4 – Ø19 | 19 |
| 80 | H100-0080 | 310 | 200 | 160 | 326 | 8 – Ø19 | 19 |
| 100 | H100-0100 | 350 | 220 | 180 | 371 | 8 – Ø19 | 19 |
| 125 | H100-0125 | 350 | 250 | 210 | 371 | 8 – Ø19 | 19 |
| 150 | H100-0150 | 480 | 285 | 240 | 478 | 8 – Ø23 | 19 |
| 200 | H100-0200 | 600 | 340 | 295 | 579 | 8 – Ø23 / 12 – Ø23 | 20 |
| 250 | H100-0250 | 730 | 405 | 350 / 355 | 681 | 12 – Ø23 / 12 – Ø28 | 22 |
| 300 | H100-0300 | 850 | 445 / 460 | 400 / 410 | 758 | 12 – Ø23 / 12 – Ø28 | 24.5 |
| 350 | H100-0350 | 980 | 505 / 520 | 460 / 470 | 849 | 16 – Ø23 / 16 – Ø28 | 24.5 |
| 400 | H100-0400 | 1,100 | 565 / 580 | 515 / 525 | 916 | 16 – Ø26 / 16 – Ø31 | 24.5 |
| 500 | H100-0500 | 1,250 | 670 / 715 | 620 / 650 | 1,080 | 20 – Ø26 / 20 – Ø34 | 26.5 |
| 600 | H100-0600 | 1,450 | 780 / 840 | 725 / 770 | 1,260 | 20 – Ø30 / 20 – Ø37 | 30 |
Practical Applications of the ShinYi H100 Float Control Valve
With its specialized design and high durability, the ShinYi H100 float control valve is widely used in various water supply systems and infrastructure projects. The product is not only suitable for residential-scale applications but is also trusted in large industrial systems:
- Domestic water storage tanks are used in apartment buildings, residential areas, and households.
- Urban water supply systems: Used in pumping stations and intermediate reservoirs to ensure a continuous and safe water supply.
- Clean water treatment plants: Controls water levels in settling tanks and filtration tanks, preventing overflow or depletion.
- Agricultural irrigation systems: Help maintain stable water levels in ponds, reservoirs, or storage tanks used for irrigation.
- Industrial zones and manufacturing plants: Applied in technical storage tanks to ensure stable operation processes and reduce the need for manual supervision.
Economic Benefits of Using the ShinYi H100 Float Control Valve
Beyond operational stability, the ShinYi H100 float control valve helps both businesses and end users optimise various costs throughout its lifecycle:
- Energy savings: The valve operates entirely by hydraulics without requiring electricity, reducing long-term energy expenses.
- Lower maintenance costs: Its design minimizes debris intrusion, reduces damage, and extends equipment lifespan, thereby decreasing repair frequency.
- Improved operational efficiency: Automatic water level control reduces the need for manual supervision and streamlines workflow processes.
- Reduced risk of damage: Prevents tank overflow or depletion, minimizing water loss and potential property damage.
- Long-term investment: With premium materials such as ductile iron, stainless steel 304, and EPDM diaphragms, the product maintains excellent durability for many years, delivering sustainable economic value.
Installation & Maintenance Guide for the ShinYi H100 Float Control Valve
To ensure the ShinYi H100 float control valve operates efficiently and remains durable, it is essential to follow the installation and maintenance procedures recommended by the manufacturer:
Installation Instructions
- Prepare clean piping: Before installation, flush out any debris or impurities in the pipeline to prevent interference with valve operation.
- Install according to flow direction: The float valve must be installed following the arrow marked on the valve body to ensure proper operation.
- Connect to the control float: Attach the float at the appropriate position in the tank/reservoir so the valve can open and close accurately according to the water level.
- Use proper sealing gaskets: When installing with flanges, use standard rubber gaskets to prevent leakage.
- Integrate auxiliary devices: It is recommended to install a shut-off valve, strainer, and pressure gauge upstream of the float valve for easier monitoring and maintenance.
Maintenance Instructions
- Periodic inspection: The valve should be checked every 3–6 months to detect early signs of wear, leakage, or float sticking.
- Clean the float and strainer: Ensure the float and all openings remain clean to prevent debris from obstructing operation.
- Replace gaskets or diaphragms when necessary: If the valve’s opening/closing response becomes sluggish, replace the gasket or diaphragm to maintain performance.
- Store in a dry environment when not in use: If the valve is not installed immediately, keep it in a dry, ventilated warehouse to prevent rust.
The above provides an overview of the ShinYi float valve and its operating guidelines. If you are looking for a reliable supplier of genuine ShinYi H100 float valves at competitive prices, contact Bao Tin Steel, a trusted distributor of steel pipes, industrial valves, and fire-fighting equipment.